| 
 Name  | 
|
| 
 Comment  | 
 STPASA_CASESOLUTION holds one record containing results pertaining to each entire solution  | 
| 
 STPASA_CASESOLUTION is public data. Source STPASA_CASESOLUTION is updated each STPASA run (i.e. every 2 hours). Volume Rows per day: 12 Mb per month: <1  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 RUN_DATETIME  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 RUN_DATETIME  | 
 DATE  | 
 X  | 
 Unique Timestamp Identifier for this study  | 
| 
 PASAVERSION  | 
 VARCHAR2(10)  | 
 
  | 
 Version of the PASA solver used to solve this case  | 
| 
 RESERVECONDITION  | 
 NUMBER(1,0)  | 
 
  | 
 Low Reserve Condition (LRC) flag for the case (1 - LRC in the case, 0 - No LRCs in the case) for capacity run  | 
| 
 LORCONDITION  | 
 NUMBER(1,0)  | 
 
  | 
 Lack of Reserve Condition (LOR) flag for the case indicates the most severe condition in the case (3 = LOR3, 2 = LOR2, 1 = LOR1, 0 = No LOR)  | 
| 
 CAPACITYOBJFUNCTION  | 
 NUMBER(12,3)  | 
 
  | 
 Objective Function from the Capacity Adequacy run  | 
| 
 CAPACITYOPTION  | 
 NUMBER(12,3)  | 
 
  | 
 Not populated as of 2005 End of Year Release; was the demand forecast used for capacity adequacy assessment. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%  | 
| 
 MAXSURPLUSRESERVEOPTION  | 
 NUMBER(12,3)  | 
 
  | 
 Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum surplus Reserve. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%  | 
| 
 MAXSPARECAPACITYOPTION  | 
 NUMBER(12,3)  | 
 
  | 
 Not populated as of 2005 End of Year Release; was the demand forecast used for assessment of Maximum Spare Capacity. 0 if no assessment, 1 for 10%, 2 for 50%, 3 for 90%  | 
| 
 INTERCONNECTORFLOWPENALTY  | 
 NUMBER(12,3)  | 
 
  | 
 The penalty for non-zero interconnector flow  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 Date and time the record was created or modified  | 
| 
 RELIABILITYLRCDEMANDOPTION  | 
 NUMBER(12,3)  | 
 
  | 
 Specifies the Probability of Exceedence (POE) demand forecast for Reliability LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)  | 
| 
 OUTAGELRCDEMANDOPTION  | 
 NUMBER(12,3)  | 
 
  | 
 Specifies the Probability of Exceedence (POE) demand forecast for outage LRC assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)  | 
| 
 LORDEMANDOPTION  | 
 NUMBER(12,3)  | 
 
  | 
 Specifies the Probability of Exceedence (POE) demand forecast for LOR assessment (0 if no assessment, 10 for 10%, 50 for 50%, 90 for 90%)  | 
| 
 RELIABILITYLRCCAPACITYOPTION  | 
 VARCHAR2(10)  | 
 
  | 
 Generation Availability to be used in Reliability LRC run (either PASA or MARKET)  | 
| 
 OUTAGELRCCAPACITYOPTION  | 
 VARCHAR2(10)  | 
 
  | 
 Generation Availability to be used in Outage LRC run (either PASA or MARKET)  | 
| 
 LORCAPACITYOPTION  | 
 VARCHAR2(10)  | 
 
  | 
 Generation Availability to be used in LOR run (either PASA or MARKET)  | 
| 
 LORUIGFOption  | 
 NUMBER(3,0)  | 
 
  | 
 UIGF POE forecast availability used for this option  | 
| 
 ReliabilityLRCUIGFOption  | 
 NUMBER(3,0)  | 
 
  | 
 UIGF POE forecast availability used for this option  | 
| 
 OutageLRCUIGFOption  | 
 NUMBER(3,0)  | 
 
  | 
 UIGF POE forecast availability used for this option  | 
| 
 Name  | 
|
| 
 Comment  | 
 STPASA_CONSTRAINTSOLUTION shows binding and violated constraint results from the capacity evaluation, including the RHS value.  | 
| 
 STPASA_CONSTRAINTSOLUTION is public data. Source STPASA_CONSTRAINTSOLUTION is updated each STPASA run (i.e. every 2 hours). Volume Rows per day: 19000 (est.) Mb per month: 90  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 CONSTRAINTID  | 
| 
 INTERVAL_DATETIME  | 
| 
 RUN_DATETIME  | 
| 
 RUNTYPE  | 
| 
 STUDYREGIONID  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 RUN_DATETIME  | 
 DATE  | 
 X  | 
 Unique Timestamp Identifier for this study  | 
| 
 INTERVAL_DATETIME  | 
 DATE  | 
 X  | 
 The unique identifier for the interval within this study  | 
| 
 CONSTRAINTID  | 
 VARCHAR2(20)  | 
 X  | 
 Constraint identifier (synonymous with GenConID)  | 
| 
 CAPACITYRHS  | 
 NUMBER(12,2)  | 
 
  | 
 The RHS value in the capacity evaluation.  | 
| 
 CAPACITYMARGINALVALUE  | 
 NUMBER(12,2)  | 
 
  | 
 Capacity adequacy assessment marginal value, 0 if not binding  | 
| 
 CAPACITYVIOLATIONDEGREE  | 
 NUMBER(12,2)  | 
 
  | 
 Capacity adequacy assessment violation degree for generic constraint; 0 if not violating  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 Last changed date of this record  | 
| 
 RUNTYPE  | 
 VARCHAR2(20)  | 
 X  | 
 Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR.  | 
| 
 STUDYREGIONID  | 
 VARCHAR2(20)  | 
 X  | 
 Primary Region for LP Solve (or MARKET if none).  | 
| 
 Name  | 
|
| 
 Comment  | 
 This report delivers available capacity, PASA availability and given recall period for all scheduled resources. Note that for an MNSP, DUID = LINKID in the MNSP_INTERCONNECTOR table  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 DUID  | 
| 
 INTERVAL_DATETIME  | 
| 
 RUN_DATETIME  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 RUN_DATETIME  | 
 DATE  | 
 X  | 
 STPASA run, identified by the nominal start time of the run  | 
| 
 INTERVAL_DATETIME  | 
 DATE  | 
 X  | 
 Half hour ended interval  | 
| 
 DUID  | 
 VARCHAR2(20)  | 
 X  | 
 NEM Dispatchable Unit Identifier  | 
| 
 GENERATION_MAX_AVAILABILITY  | 
 NUMBER(12,6)  | 
 
  | 
 Available Capacity for a scheduled generating unit, semi-scheduled generating unit, BDU (Gen side), WDR or MNSP.  | 
| 
 GENERATION_PASA_AVAILABILITY  | 
 NUMBER(12,0)  | 
 
  | 
 PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit.  | 
| 
 GENERATION_RECALL_PERIOD  | 
 NUMBER(8,3)  | 
 
  | 
 Recall Period associated with the PASA Availability for a scheduled generating unit, BDU (Gen side), WDR or MNSP. Null for a semi-scheduled generating unit.  | 
| 
 LOAD_MAX_AVAILABILITY  | 
 NUMBER(12,6)  | 
 
  | 
 Available Capacity for a scheduled load or BDU(Load side).  | 
| 
 LOAD_PASA_AVAILABILITY  | 
 NUMBER(12,0)  | 
 
  | 
 PASA Availability for a scheduled load or BDU(Load side).  | 
| 
 LOAD_RECALL_PERIOD  | 
 NUMBER(8,3)  | 
 
  | 
 Recall Period associated with the PASA Availability for a scheduled load or BDU(Load side).  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 Report Creation Date Time  | 
| 
 Name  | 
|
| 
 Comment  | 
 STPASA_INTERCONNECTORSOLN shows the results of the capacity evaluation for Interconnectors, including the calculated limits for the interval.  | 
| 
 STPASA_INTERCONNECTORSOLN is public so is available to all participants. Source STPASA_INTERCONNECTORSOLN is updated each STPASA run (i.e. every 2 hours). Volume Rows per day: 576 Mb per month: 4  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 INTERCONNECTORID  | 
| 
 INTERVAL_DATETIME  | 
| 
 RUN_DATETIME  | 
| 
 RUNTYPE  | 
| 
 STUDYREGIONID  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 RUN_DATETIME  | 
 DATE  | 
 X  | 
 Unique Timestamp Identifier for this study  | 
| 
 INTERVAL_DATETIME  | 
 DATE  | 
 X  | 
 The unique identifier for the interval within this study  | 
| 
 INTERCONNECTORID  | 
 VARCHAR2(10)  | 
 X  | 
 Interconnector Identifier  | 
| 
 CAPACITYMWFLOW  | 
 NUMBER(12,2)  | 
 
  | 
 Interconnector loading level (MW) that can be reached in case of capacity scarcity in neighbouring regions subject to network and energy constraints  | 
| 
 CAPACITYMARGINALVALUE  | 
 NUMBER(12,2)  | 
 
  | 
 Capacity adequacy assessment marginal value, 0 if not binding  | 
| 
 CAPACITYVIOLATIONDEGREE  | 
 NUMBER(12,2)  | 
 
  | 
 Capacity adequacy assessment violation degree for interconnector capacity; 0 if not violating  | 
| 
 CALCULATEDEXPORTLIMIT  | 
 NUMBER(12,2)  | 
 
  | 
 Calculated Interconnector limit of exporting energy on the basis of invoked constraints and static interconnector export limit  | 
| 
 CALCULATEDIMPORTLIMIT  | 
 NUMBER(12,2)  | 
 
  | 
 Calculated Interconnector limit of importing energy on the basis of invoked constraints and static interconnector import limit. Note unlike the input interconnector import limit this is a directional quantity and should be defined with respect to the interconnector flow.  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 Last changed date of this record  | 
| 
 RUNTYPE  | 
 VARCHAR2(20)  | 
 X  | 
 Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR.  | 
| 
 EXPORTLIMITCONSTRAINTID  | 
 VARCHAR2(20)  | 
 
  | 
 ID of the constraint that sets the Interconnector Export Limit  | 
| 
 IMPORTLIMITCONSTRAINTID  | 
 VARCHAR2(20)  | 
 
  | 
 ID of the constraint that sets the Interconnector Import Limit  | 
| 
 STUDYREGIONID  | 
 VARCHAR2(20)  | 
 X  | 
 Primary Region for LP Solve (or MARKET if none).  | 
| 
 Name  | 
|
| 
 Comment  | 
 STPASA_REGIONSOLUTION shows the results of the regional capacity, maximum surplus reserve and maximum spare capacity evaluations for each period of the study.Note that the RELIABILITY_LRC and OUTAGE_LRC Run Types are no longer reported from 31 July 2025.  | 
| 
 STPASA_REGIONSOLUTION is public so is available to all participants. Source STPASA_REGIONSOLUTION is updated each STPASA run (i.e every 2 hours). Volume Rows per day: 480 Mb per month: 8  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 INTERVAL_DATETIME  | 
| 
 REGIONID  | 
| 
 RUN_DATETIME  | 
| 
 RUNTYPE  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 RUN_DATETIME  | 
 DATE  | 
 X  | 
 Unique Timestamp Identifier for this run, identified by the nominal start time of the run  | 
| 
 INTERVAL_DATETIME  | 
 DATE  | 
 X  | 
 End date time of the interval  | 
| 
 REGIONID  | 
 VARCHAR2(10)  | 
 X  | 
 Region Identifier  | 
| 
 DEMAND10  | 
 NUMBER(12,2)  | 
 
  | 
 10% Probability of Exceedance demand forecast  | 
| 
 DEMAND50  | 
 NUMBER(12,2)  | 
 
  | 
 50% Probability of Exceedance demand forecast  | 
| 
 DEMAND90  | 
 NUMBER(12,2)  | 
 
  | 
 90% Probability of Exceedance demand forecast  | 
| 
 RESERVEREQ  | 
 NUMBER(12,2)  | 
 
  | 
 Reserve Requirement (MW). This field is not populated after 30 July 2025.  | 
| 
 CAPACITYREQ  | 
 NUMBER(12,2)  | 
 
  | 
 Demand + Reserve requirements (MW). This field is not populated after 30 July 2025.  | 
| 
 ENERGYREQDEMAND50  | 
 NUMBER(12,2)  | 
 
  | 
 Sum of: (Region Demand50)/Period (sum by trading day, entered in first period of trading day, GWh)  | 
| 
 UNCONSTRAINEDCAPACITY  | 
 NUMBER(12,0)  | 
 
  | 
 Aggregate generation + WDR capacity from Non-Energy Constrained plant subjected to restrictions due to network constraints  | 
| 
 CONSTRAINEDCAPACITY  | 
 NUMBER(12,0)  | 
 
  | 
 Aggregate generation + WDR capacity from Energy Constrained plant subjected to restrictions due to network constraints  | 
| 
 NETINTERCHANGEUNDERSCARCITY  | 
 NUMBER(12,2)  | 
 
  | 
 Net export (MW) out of this region in the LOR evaluation. Export if 0, Import if 0. This value is the same as LORNETINTERCHANGEUNDERSCARCITY.  | 
| 
 SURPLUSCAPACITY  | 
 NUMBER(12,2)  | 
 
  | 
 Regional surplus capacity (MW), +/- values indicate surplus/deficit capacity respectively. This value reflects Regional LOR reserve.  | 
| 
 SURPLUSRESERVE  | 
 NUMBER(12,2)  | 
 
  | 
 Regional surplus reserve (MW). This value also reflects Regional LOR reserve. Note: For LOR runs, RESERVEREQ requirement input is not used.  | 
| 
 RESERVECONDITION  | 
 NUMBER(1,0)  | 
 
  | 
 Regional reserve condition from LRC run. This field is not populated after 30 July 2025.  | 
| 
 MAXSURPLUSRESERVE  | 
 NUMBER(12,2)  | 
 
  | 
 Maximum Surplus Reserve (MW) evaluated for this region from LRC runs. This field is no longer populated.  | 
| 
 MAXSPARECAPACITY  | 
 NUMBER(12,2)  | 
 
  | 
 Maximum Spare Capacity (MW) evaluated for this region. Calculated for each region in turn. This value reflects Regional LOR reserve.  | 
| 
 LORCONDITION  | 
 NUMBER(1,0)  | 
 
  | 
 The LOR Condition determined from the Maximum Spare Capacity value: 0 - no condition, 1 - LOR1 condition, 2 - LOR2 condition, 3 - LOR3 condition  | 
| 
 AGGREGATECAPACITYAVAILABLE  | 
 NUMBER(12,2)  | 
 
  | 
 Sum of MAXAVAIL quantities offered by all Scheduled units and Availability of all semi-scheduled units limited by MAXAVAIL in a given Region for a given PERIODID  | 
| 
 AGGREGATESCHEDULEDLOAD  | 
 NUMBER(12,2)  | 
 
  | 
 Sum of MAXAVAIL quantities bid by of all Scheduled Loads in a given Region for a given PERIODID.  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 Date time this record was created  | 
| 
 AGGREGATEPASAAVAILABILITY  | 
 NUMBER(12,0)  | 
 
  | 
 Sum of PASAAVAILABILITY for all scheduled generating units and scheduled bidirectional units (Gen side) with a Recall_Period = 24 hours plus the sum of Unconstrained Intermittent Generation Forecasts (UIGF) for all semi-scheduled generating units. For the RELIABILITY_LRC and OUTAGE_LRC runs, UIGF is the POE90 forecast. For the LOR Run, UIGF is the POE50 forecast. Note that the RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025.  | 
| 
 RUNTYPE  | 
 VARCHAR2(20)  | 
 X  | 
 Type of run. Values are RELIABILITY_LRC, OUTAGE_LRC and LOR. Note that the STPASA RELIABILITY_LRC and OUTAGE_LRC Run Types are discontinued from 31 July 2025, with only the LOR Run Type reported.  | 
| 
 ENERGYREQDEMAND10  | 
 NUMBER(12,2)  | 
 
  | 
 Energy (GWh) required for this energy block based on the 10% probability of exceedance demand. Listed in the first interval of the energy block  | 
| 
 CALCULATEDLOR1LEVEL  | 
 NUMBER(16,6)  | 
 
  | 
 Region Reserve Level for LOR1 used. Can be static value or calculated value if an interconnector is a credible contingency  | 
| 
 CALCULATEDLOR2LEVEL  | 
 NUMBER(16,6)  | 
 
  | 
 Region Reserve Level for LOR2 used. Can be static value or calculated value if an interconnector is a credible contingency  | 
| 
 MSRNETINTERCHANGEUNDERSCARCITY  | 
 NUMBER(12,2)  | 
 
  | 
 Net interconnector flow from the region for this interval from the MSR assessment. This field is no longer populated.  | 
| 
 LORNETINTERCHANGEUNDERSCARCITY  | 
 NUMBER(12,2)  | 
 
  | 
 Net interconnector flow from the region for this interval from the LOR assessment  | 
| 
 TOTALINTERMITTENTGENERATION  | 
 NUMBER(15,5)  | 
 
  | 
 Allowance made for non-scheduled generation in the demand forecast (MW).  | 
| 
 DEMAND_AND_NONSCHEDGEN  | 
 NUMBER(15,5)  | 
 
  | 
 Sum of Cleared Scheduled generation, imported generation (at the region boundary) and allowances made for non-scheduled generation (MW).  | 
| 
 UIGF  | 
 NUMBER(12,2)  | 
 
  | 
 Regional aggregated Unconstrained Intermittent Generation Forecast of Semi-scheduled generation (MW).  | 
| 
 SEMISCHEDULEDCAPACITY  | 
 NUMBER(12,2)  | 
 
  | 
 Constrained generation forecast (MW) for semi-scheduled units for the region. For RELIABILITY_LRC run, semi-scheduled generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run, semi-scheduled generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.  | 
| 
 LOR_SEMISCHEDULEDCAPACITY  | 
 NUMBER(12,2)  | 
 
  | 
 Constrained generation forecast for semi-scheduled units for the region for the LOR run. Semi-scheduled generation is constrained by both System Normal and Outage constraints, and incorporate MAXAVAIL limits.  | 
| 
 LCR  | 
 NUMBER(16,6)  | 
 
  | 
 Largest Credible Risk. MW value for highest credible contingency  | 
| 
 LCR2  | 
 NUMBER(16,6)  | 
 
  | 
 Two Largest Credible Risks. MW value for highest two credible contingencies.  | 
| 
 FUM  | 
 NUMBER(16,6)  | 
 
  | 
 Forecasting Uncertainty Measure. MW value of reserve calculated as defined in the Reserve Level Declaration Guidelines  | 
| 
 SS_SOLAR_UIGF  | 
 Number(12,2)  | 
 
  | 
 Unconstrained Intermittent Generation Forecast for solar for the region. For RELIABILITY_LRC and OUTAGE_LRC run this is the POE90 forecast (determined by LRCUIGFOption in CaseSolution). For LOR run this is the POE50 forecast  | 
| 
 SS_WIND_UIGF  | 
 Number (12,2)  | 
 
  | 
 Unconstrained Intermittent Generation Forecast for wind for the region. For RELIABILITY_LRC and OUTAGE_LRC run this is the POE90 forecast (determined by LRCUIGFOption in CaseSolution). For LOR run this is the POE50 forecast  | 
| 
 SS_SOLAR_CAPACITY  | 
 Number (12,2)  | 
 
  | 
 Constrained generation forecast for solar for the region. For RELIABILITY_LRC run solar generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run solar generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.  | 
| 
 SS_WIND_CAPACITY  | 
 Number (12,2)  | 
 
  | 
 Constrained generation forecast for wind for the region. For RELIABILITY_LRC run wind generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run wind generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.  | 
| 
 SS_SOLAR_CLEARED  | 
 Number (12,2)  | 
 
  | 
 Constrained generation forecast (MW) for solar for the region. For RELIABILITY_LRC run, solar generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run, solar generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.This value is the same as SS_SOLAR_CAPACITY.  | 
| 
 SS_WIND_CLEARED  | 
 Number (12,2)  | 
 
  | 
 Constrained generation forecast (MW) for wind for the region. For RELIABILITY_LRC run, wind generation is constrained only by System Normal constraints. For OUTAGE_LRC run and LOR run, wind generation is constrained by both System Normal and Outage constraints. All three run types (RELIABILITY_LRC, OUTAGE_LRC, LOR) incorporate MAXAVAIL limits.This value is the same as SS_WIND_CAPACITY.  | 
| 
 WDR_AVAILABLE  | 
 NUMBER(12,2)  | 
 
  | 
 Regional aggregated Wholesale Demand Response (WDR) availability in MW.  | 
| 
 WDR_PASAAVAILABLE  | 
 NUMBER(12,2)  | 
 
  | 
 Regional aggregated Wholesale Demand Response (WDR) PASA availability in MW.  | 
| 
 WDR_CAPACITY  | 
 NUMBER(12,2)  | 
 
  | 
 Regional aggregated Wholesale Demand Response (WDR) capacity in MW.  | 
  | 
  | 
  |