 Name  | 
|
| 
 Comment  | 
 NETWORK_EQUIPMENTDETAIL Provides details on equipment that may have outages or ratings. A single piece of equipment may have multiple records if its details change.  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 ELEMENTID  | 
| 
 EQUIPMENTID  | 
| 
 EQUIPMENTTYPE  | 
| 
 SUBSTATIONID  | 
| 
 VALIDFROM  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 SUBSTATIONID  | 
 VARCHAR(30)  | 
 X  | 
 ID uniquely identifying the substation this equipment is located at  | 
| 
 EQUIPMENTTYPE  | 
 VARCHAR(10)  | 
 X  | 
 The type of equipment. Valid values are:  | 
| 
 EQUIPMENTID  | 
 VARCHAR(30)  | 
 X  | 
 A unique identifier for this type of equipment at this substation  | 
| 
 VALIDFROM  | 
 TIMESTAMP(3)  | 
 X  | 
 The date that this record is applies from (inclusive)  | 
| 
 VALIDTO  | 
 TIMESTAMP(3)  | 
 
  | 
 The date that this record applies until (exclusive)  | 
| 
 VOLTAGE  | 
 VARCHAR(20)  | 
 
  | 
 The voltage in KV for this equipment.  | 
| 
 DESCRIPTION  | 
 VARCHAR(100)  | 
 
  | 
 A short description for this equipment.  | 
| 
 LASTCHANGED  | 
 TIMESTAMP(3)  | 
 
  | 
 The time that this record was last changed.  | 
| 
 ELEMENTID  | 
 NUMBER(15,0)  | 
 X  | 
 Equipment element id  | 
| 
 Name  | 
|
| 
 Comment  | 
 NETWORK_OUTAGECONSTRAINTSET lists the Constraint Set or Sets that are expected to be invoked for the outage once it is confirmed to proceed.  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 GENCONSETID  | 
| 
 OUTAGEID  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 OUTAGEID  | 
 NUMBER(15,0)  | 
 X  | 
 ID uniquely identifying the outage  | 
| 
 GENCONSETID  | 
 VARCHAR(50)  | 
 X  | 
 ID for the constraint set  | 
| 
 STARTINTERVAL  | 
 DATE  | 
 
  | 
 The dispatch interval that this constraint applies from  | 
| 
 ENDINTERVAL  | 
 DATE  | 
 
  | 
 The dispatch interval that this constraint applies until.  | 
| 
 Name  | 
|
| 
 Comment  | 
 Lists asset owners planned outages for transmission equipment. This also includes details for transmission equipment that will not have an outage, but associated secondary equipment has an outage and a related constraint set may be invoked. This scenario is indicated by the ISSECONDARY field in the table  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 ELEMENTID  | 
| 
 EQUIPMENTID  | 
| 
 EQUIPMENTTYPE  | 
| 
 OUTAGEID  | 
| 
 STARTTIME  | 
| 
 SUBSTATIONID  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 OUTAGEID  | 
 NUMBER(15,0)  | 
 X  | 
 ID uniquely identifying the outage  | 
| 
 SUBSTATIONID  | 
 VARCHAR(30)  | 
 X  | 
 The substation this equipment is located at  | 
| 
 EQUIPMENTTYPE  | 
 VARCHAR(10)  | 
 X  | 
 The type of equipment. Valid values are:  | 
| 
 EQUIPMENTID  | 
 VARCHAR(30)  | 
 X  | 
 A unique identifier for this equipment at this substation, and based on its type  | 
| 
 STARTTIME  | 
 DATE  | 
 X  | 
 The planned starting date and time of the outage  | 
| 
 ENDTIME  | 
 DATE  | 
 
  | 
 The planned ending date and time of the outage  | 
| 
 SUBMITTEDDATE  | 
 DATE  | 
 
  | 
 The date and time this outage was first submitted  | 
| 
 OUTAGESTATUSCODE  | 
 VARCHAR(10)  | 
 
  | 
 A code representing the status of the outage.  | 
| 
 RESUBMITREASON  | 
 VARCHAR(50)  | 
 
  | 
 Changes to an outage key details may require the outage to be resubmitted.  | 
| 
 RESUBMITOUTAGEID  | 
 NUMBER(15,0)  | 
 
  | 
 The new outage id created from a resubmit.  | 
| 
 RECALLTIMEDAY  | 
 NUMBER(10,0)  | 
 
  | 
 The recall time in minutes during the day  | 
| 
 RECALLTIMENIGHT  | 
 NUMBER(10,0)  | 
 
  | 
 The recall time in minutes during the night  | 
| 
 LASTCHANGED  | 
 TIMESTAMP(3)  | 
 
  | 
 The time that this record was last changed  | 
| 
 REASON  | 
 VARCHAR2(100)  | 
 
  | 
 The reason provided by the asset owner for this outage  | 
| 
 ISSECONDARY  | 
 NUMBER(1,0)  | 
 
  | 
 1 = The outage is for a secondary piece of equipment that has an associated constraint set. The transmission equipment is still in service. 0 = The outage is for the transmission equipment  | 
| 
 ACTUAL_STARTTIME  | 
 DATE  | 
 
  | 
 The actual starting date/time of the outage  | 
| 
 ACTUAL_ENDTIME  | 
 DATE  | 
 
  | 
 The actual ending date/time of the outage  | 
| 
 COMPANYREFCODE  | 
 VARCHAR2(20)  | 
 
  | 
 The asset owners reference code for this outage  | 
| 
 ELEMENTID  | 
 NUMBER(15,0)  | 
 X  | 
 Equipment element id  | 
| 
 Name  | 
|
| 
 Comment  | 
 NETWORK_OUTAGESTATUSCODE describes the different outage status codes  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 OUTAGESTATUSCODE  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 OUTAGESTATUSCODE  | 
 VARCHAR(10)  | 
 X  | 
 A code representing the status of an outage  | 
| 
 DESCRIPTION  | 
 VARCHAR(100)  | 
 
  | 
 A description of the status code  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 The time that this record was last changed  | 
| 
 Name  | 
|
| 
 Comment  | 
 NETWORK_RATING defines a list of the equipment ratings that may be used as inputs to market constraints.  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 SPD_ID  | 
| 
 VALIDFROM  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 SPD_ID  | 
 VARCHAR(21)  | 
 X  | 
 ID defining this data source for use in constraints  | 
| 
 VALIDFROM  | 
 DATE  | 
 X  | 
 The date that this record is applies from (inclusive)  | 
| 
 VALIDTO  | 
 DATE  | 
 
  | 
 The date that this record applies until (exclusive)  | 
| 
 REGIONID  | 
 VARCHAR(10)  | 
 
  | 
 The region that this rating is for  | 
| 
 SUBSTATIONID  | 
 VARCHAR(30)  | 
 
  | 
 The substation the equipment is located at  | 
| 
 EQUIPMENTTYPE  | 
 VARCHAR(10)  | 
 
  | 
 The type of equipment. Valid values are:  | 
| 
 EQUIPMENTID  | 
 VARCHAR(30)  | 
 
  | 
 A unique identifier for this equipment at this substation, and based on its type  | 
| 
 RATINGLEVEL  | 
 VARCHAR(10)  | 
 
  | 
 The rating level of the value used, one of:  | 
| 
 ISDYNAMIC  | 
 NUMBER(1,0)  | 
 
  | 
 One of:  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 The time that this record was last changed  | 
| 
 Name  | 
|
| 
 Comment  | 
 The NETWORK_REALTIMERATING table shows the equipment rating values in MVA used as inputs to constraints in the dispatch solution. This includes values for both static and dynamic ratings. The NETWORK_RATING table can be used to determine the physical equipment the rating is for based on the SPD_ID value.  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 SETTLEMENTDATE  | 
| 
 SPD_ID  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 SETTLEMENTDATE  | 
 DATE  | 
 X  | 
 The dispatch interval the rating applies to  | 
| 
 SPD_ID  | 
 VARCHAR(21)  | 
 X  | 
 ID defining this data source for use in constraints  | 
| 
 RATINGVALUE  | 
 NUMBER(16,6)  | 
 X  | 
 The defined equipment rating value in MVA  | 
| 
 Name  | 
|
| 
 Comment  | 
 NETWORK_STATICRATING lists the static rating values that will apply for a Rating Application ID.  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 APPLICATIONID  | 
| 
 EQUIPMENTID  | 
| 
 EQUIPMENTTYPE  | 
| 
 RATINGLEVEL  | 
| 
 SUBSTATIONID  | 
| 
 VALIDFROM  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 SUBSTATIONID  | 
 VARCHAR(30)  | 
 X  | 
 The substation the equipment is located at  | 
| 
 EQUIPMENTTYPE  | 
 VARCHAR(10)  | 
 X  | 
 The type of equipment. Valid values are:  | 
| 
 EQUIPMENTID  | 
 VARCHAR(30)  | 
 X  | 
 A unique identifier for this type of equipment at this substation  | 
| 
 RATINGLEVEL  | 
 VARCHAR(10)  | 
 X  | 
 The rating level of the value used, one of:  | 
| 
 APPLICATIONID  | 
 VARCHAR(20)  | 
 X  | 
 The applicationid which defines the application timeframes of this rating.  | 
| 
 VALIDFROM  | 
 DATE  | 
 X  | 
 The date that this record is applies from (inclusive)  | 
| 
 VALIDTO  | 
 DATE  | 
 
  | 
 The date that this record applies until (exclusive)  | 
| 
 RATINGVALUE  | 
 NUMBER(16,6)  | 
 
  | 
 The rating value in MVA that applies. This may be positive or negative depending on which side of the nominal MW flow direction the rating value applies.  | 
| 
 LASTCHANGED  | 
 DATE  | 
 
  | 
 The time that this record was last changed.  | 
| 
 Name  | 
|
| 
 Comment  | 
 NETWORK_SUBSTATIONDETAIL sets out the attributes of sub-stations across time  | 
| 
 Name  | 
 Comment  | 
 Value  | 
| 
 Visibility  | 
 
  | 
 Public  | 
| 
 Name  | 
| 
 SUBSTATIONID  | 
| 
 VALIDFROM  | 
| 
 Name  | 
| 
 LASTCHANGED  | 
| 
 Name  | 
 Data Type  | 
 Mandatory  | 
 Comment  | 
| 
 SUBSTATIONID  | 
 VARCHAR(30)  | 
 X  | 
 ID uniquely identifying this substation  | 
| 
 VALIDFROM  | 
 TIMESTAMP(3)  | 
 X  | 
 The record is valid from this date (inclusive)  | 
| 
 VALIDTO  | 
 TIMESTAMP(3)  | 
 
  | 
 The record is valid up until this date (exclusive)  | 
| 
 DESCRIPTION  | 
 VARCHAR(100)  | 
 
  | 
 Description of the substation  | 
| 
 REGIONID  | 
 VARCHAR(10)  | 
 
  | 
 The NEM region the substation is in  | 
| 
 OWNERID  | 
 VARCHAR(30)  | 
 
  | 
 The TNSP who is responsible for this substation  | 
| 
 LASTCHANGED  | 
 TIMESTAMP(3)  | 
 
  | 
 The time that this record was last changed.  | 
  | 
  | 
  |